DEVA D-ATT20B RF ATTENUATOR, 20DB, 50 OHM, BNC MALE TO BNC FEMALE, 2 WATTS < 3 GHZ

DEVA D-ATT20B RF ATTENUATOR, 20DB, 50 OHM, BNC MALE TO BNC FEMALE, 2 WATTS < 3 GHZ

MCI 61101-N MOTORIZED COAXIAL SWITCH 4 PORT N CONNECTOR W: 5 LBS SD: 10 X 10 X 8 IN ONE PORT CAPPED TO MAKE IT A 3 PORT

MCI 61101-N MOTORIZED COAXIAL SWITCH 4 PORT N CONNECTOR W: 5 LBS SD: 10 X 10 X 8 IN ONE PORT CAPPED TO MAKE IT A 3 PORT

DEVA AC-RE2 AC POWER SUPPLY FOR RADIO EXPLORER II

SKU
DEV-AC-RE2
MFR#
AC-RE2
was $45.00 Special Price $42.75
Availability: Out of stock
DEVA AC-RE2 - AC Power Supply for Radio Explorer II

SPECIAL SHIPPING RATES

On orders over $1000

WHOLESALING PRICING

Ask us how to become a Wholesaler

SECURED PAYMENT

Guaranteed safe payment options
Desktop power supply. Output voltage 12V, Output current 4.17A, Power 50W, Wide range input 90-264V, Output connector RE2-XLR, cable length 1.4m. Suitable power cord IEC 320 C13 „PC cable“.
Your Rating

Specifications:

GENERAL
Voltage DC 12V
Loading 0 to 4.17A
Tolerance ±5%
OCP 5.2 to 9.0A
OVP max 16V
Efficiency >87%
Max. Power 50W
Ripple & Noise 200mV p-p
Connector UL Approved 2.1 x 5.5 x 11mm
INPUT
Voltage 90 to 264 VAC
Frequency 47 to 63 Hz
Current 1.5A rms@ AC low line input and DC output full load
Inrush Surge Current (cold start) 40/60A max. @ power supply cold start, ambient temperature 25°C @115Vac/230Vac nominal AC input.
Leakage current <0.25mA max
PROTECTION
Over Current/Short protection The power supply will self-protect any output to ground, and auto recovery when abnormal circuit faults remove. An output short circuit is defined as any output impedance of less than 0.1 ohms. OCP method: Fold back
Over Voltage OVP Voltage limiting
Input protection F1:T3.15AL/250V Fuse
No load protection The power supply is provided with no load operation to prevent the power supply and system from damage
Protection class I
OTHERS
Dielectric Strength (Hi-pot) Primary to Secondary: 3000VAC / 10mA / 60s
M.T.B.F 500,000 Calculated Hours at 25°C, by Telcordia SR-332
Cable length 1185#16*1C / 4ft (1,2m) round cable
PLD (power line disturbance ) LINE POWER SURGE | LINE VOLTAGE SAG
Cooling method By natural air
Housing material PC or PPO
Temperature coefficient <±0.5%/°C
OPERATING CONDITIONS
Temperature 0 to 40°C
Humidity 8 to 90% RH non condensing
SAFETY
Standards CE | TUV/GS | CB | cULus | FCC| | VCCI | PSE | EAC | S-Mark | RCM
EMC - EMI EN 55022 Class B (2006)+ A1(2007)
EN 61000-3-2 (2006) + A1(2009) + A2 Class A(2009)/EN 61000-3-3 (2008)
EMC - EMS EN55024(1998)+A1(2001)+A2(2003) | IEC 61000-4-2 (2008) | IEC 61000-4-3 (2006) + A1(2007) + A2(2010)
IEC 61000-4-4 (2004) + A1(2010) |IEC 61000-4-5 (2005) | IEC 61000-4-6 (2008) | IEC 61000-4-8 (2009) | IEC 61000-4-11 (2004)
Size and Weight
Shipping Weight (W;H;D) 430 x 250 x 480mm / 300g
main product photo